Storefronts, offices, lobbies, hospitality environments, address signs, wayfinding, wall logos, branded interiors, exterior façades, and multi-location commercial programs.
Precision-cut letters and logos for clean architectural branding.
Flat-Cut Letters & Logos create a refined dimensional presentation without internal illumination. Each element is precision cut from aluminum, 304 stainless steel, acrylic, or PVC, then finished and prepared for flush or standoff mounting.
A clean dimensional silhouette with crisp edges and a refined material finish. Flush mounting creates a minimal profile; standoffs add depth and a controlled shadow line.
Artwork feasibility, minimum stroke width, material, thickness, finish, mounting method, wall conditions, templates, hardware, shipping, and production requirements.
Fabrication data for Flat-Cut Letters & Logos.
Review construction, dimensional planning, mounting systems, materials, finishes, installation preparation, and quote requirements.
Primary production specifications.
Final construction depends on the approved artwork, minimum stroke width, material, thickness, finish, mounting method, wall conditions, scale, exposure, and installation requirements.
Artwork geometry and material depth determine flat-cut feasibility.
Stroke width, counters, bridges, overall dimensions, selected depth, unsupported spans, mounting locations, weight, and finish are reviewed together.
Project-specific flat-cut planning
The following factors determine the final material and production method.
Minimum strokes, counters, bridges, corners, and connected shapes are reviewed before production.
Depths up to 1" are available. Scale, rigidity, finish, weight, environment, mounting, and material availability determine the final specification.
Stud spacing, standoffs, wall type, templates, access, and installer requirements are confirmed early.
How Flat-Cut Letters & Logos are produced and mounted.
Compare the finished dimensional appearance with the two common mounting configurations, then review the primary fabrication stages.
Flat-Cut Letters & Logos
Artwork is precision cut from sheet material, finished to the approved specification, and prepared for flush or standoff mounting.
The left diagram shows a close-to-wall flush installation; the right shows spacer-supported mounting for added depth and shadow.
The material face and edge define the appearance, while the selected mounting method controls profile depth and shadow.
Contours, counters, bridges, corners, and the 10 mm minimum stroke standard are reviewed before production.
Common depths are 1/4", 1/2", and 3/4", with depths available up to 1". Final selection is coordinated with finish, scale, rigidity, weight, exposure, and mounting.
The selected production process creates the approved face, edges, openings, and mounting provisions.
Painting, brushing, polishing, plating, material color, edge finishing, and protective treatment are completed as specified.
Mounting locations, hardware, standoff depth, patterns, and installation notes are prepared for the approved wall condition.
Mounting selected around the desired profile and wall condition.
Flush and standoff installations are both available. Stud type, spacer depth, fastener locations, adhesives, templates, and access are confirmed before fabrication.
Flush mounting keeps the letters close to the wall for a minimal profile. Standoff mounting creates additional depth and a controlled shadow line.
Studs or mechanical fasteners hold the element close to the substrate with minimal visible separation.
Spacers establish a controlled offset for added dimensionality, shadow, and surface clearance.
Concrete, masonry, wood, drywall, metal panels, and specialty façades require different anchors and access planning.
Fasteners are distributed around the design to support alignment, rigidity, and installation access.
Spacer length is selected around the desired shadow, profile, cleaning access, and wall irregularities.
Approved tapes or adhesives may supplement mechanical mounting for suitable lightweight interior applications.
Paper patterns can identify outlines, baselines, stud holes, spacing, and alignment reference points.
Access, lifts, wall preparation, drilling, anchors, tolerances, and field conditions are documented early.
Materials selected around appearance, durability, and installation.
Material, depth, color matching, metallic-finish eligibility, edge treatment, environment, mounting, weight, and brand standards are coordinated as one specification.
Common depths include 1/4", 1/2", and 3/4", with options up to 1" subject to project review. Available with Pantone/PMS or Sherwin-Williams matched paint, powder coating, anodized, brushed, and other compatible metal finishes.
Common depths include 1/4", 1/2", and 3/4", with options up to 1" subject to project review. Available with Pantone/PMS or Sherwin-Williams matched paint, brushed, polished, mirror, plated, PVD-style, and other compatible finishes.
Common depths include 1/4", 1/2", and 3/4", with options up to 1" subject to sheet availability and project review. Available in solid, clear, translucent, painted, printed, layered, or custom-color constructions. Metallic metal finishes are not applied to acrylic.
Painted finishes can be matched to supplied Pantone/PMS or Sherwin-Williams color codes, subject to production approval and the selected substrate.
Brushed, polished, mirror, anodized, plated, PVD-style, and related metallic treatments are substrate-specific and available only on compatible metal materials.
Edges may remain cut, be routed, sanded, polished, painted, brushed, or otherwise finished to the approved appearance and selected substrate.
Information required for an accurate quote.
Supplying the core project details upfront helps confirm artwork feasibility, material, thickness, finish, mounting, pricing, production requirements, and lead time.
Vector artwork lets us review the 10 mm minimum stroke, contours, counters, bridges, dimensions, material, and mounting feasibility.
Vector files are preferred. Clean PDFs or high-resolution references can be used for initial review.
Send target dimensions, letter height, wall area, viewing distance, and any brand-standard drawings.
Provide a preferred material and depth when known. Common depths are 1/4", 1/2", and 3/4", with options available up to 1" subject to project review.
Provide Pantone/PMS or Sherwin-Williams color codes for painted finishes. Metallic finishes are available only on aluminum and 304 stainless steel; include the desired brushed, polished, mirror, anodized, plated, or specialty-metal reference.
Provide the desired profile, spacer depth when known, wall material, access conditions, and installer preferences.
Include wall construction, exposure, site photos, access limitations, and any permit or hardware requirements.
Provide wall material, thickness, backing, concealed conditions, and available access where known.
Confirm preferred mounting style, standoff depth, pattern requirements, and installer expectations.
Provide delivery restrictions, installation sequence, oversized-element concerns, or special protection requirements.